Medical-Surgical Mask Testing
Mcfarland Turbidity,Synthetic Bood penetration Tester(MASK/N95) | ASTM F 1862 | 1 | GESTER | GT-RA01 |
---|---|---|---|---|
Bacterial Filtraton Efficiency Tester(MASK/N95) | ASTM F 2101 | 1 | GESTER | GT-RA02B |
Differential Pressure Tester(MASK/N95) | EN14683 annex C | 1 | GESTER | GT-RA04 |
Particle filtration efficiency Tester(MASK/N95) | F2299 | 1 | GESTER | GT-RA09B-2 |
Flammability tested | 16 CFR 1610 | 1 | GESTER | GT-C32 |
Particle filtration efficiency&Differential pressure Tester(N95) | 16 CFR 84 | 1 | GESTER | GT-RA03 |
Model | GT-RA03 |
---|---|
Renge of Flow Meter | 0~400L/min,Accuracy:1% |
Renge of Digital Differrential Pressure Gauge | 0~1000Pa/Accuracy:1Pa |
Pump Capacity | ≥ 300L/min |
Printer | Micro-thermal printer |
Dimensions | 680x600x1000mm |
Head Mold | 3 sets(Large,Medium and Small) |
Power Supply | AC200V 50HZ 650W |
Weight | 50kg |
Standards | EN149-2009 section 7.15,8.3.4,8.9,EN 13274-3, GB 19063, GB2626,G/T 32610,NIOSH 42 CFR Part 84,JIS/T 8151 |
Microbial Penetration Wet (Critical area only) | EN 13795-1 | ISO 22610 | 1 | GESTER | GT-RA15 Wet-resistant Bacterial |
---|---|---|---|---|---|
Microbial Penetration Dry (Less Critical area only) | EN 13795-1 | ISO 22610:2005 | 1 | GESTER | GT-RA14 Dry Microbial Penetration Resistance Tester |
Cleanliness Microbial | EN 13795-1 | ISO 11737-1:2018,EN14683 | 1 | GESTER | Cleanliness Microbial |
Partical Release | EN 13795-1 | ISO 9073-10:2003 | 1 | GESTER | GT-RA16 Dry State Lint Tester |
Resistance liquid penetration | EN 13795-1 | ISO 811:2018 | 1 | GESTER | GT-C26A Hydrostatic Head Tester |
Brusing strength (Dry and Wet) | EN 13795-1 | ISO 13938-1:1999 | 1 | GESTER | GT-C12A Bursing Strength Tester |
Tensile strength dry-wet(critical area only) | EN 13795-1 | ISO 9073-3,EN 29073:1992 | 1 | GESTER | GT-C02-1 Universal Tensile Strength Tester (Single Column) |
Impact penetration | ANSI-AAMI PB70-2012 | AATCC 42 | 1 | GESTER | GT-C Impact Penetration Tester |
Hydrostatic Pressure | ANSI-AAMI PB70-2012 | AATCC 127 Option2 | 1 | GESTER | GT-C26A |
Synthetic Boold Penetration Test (for surgical drapes) | ANSI-AAMI PB70-2012 | AS TM F 1670 | 1 | GESTER | GT-RC01 Protective Cloting Blood Penetration Resistance |
Viral Penetration Test (for surgical and isolation gowns) | ANSI-AAMI PB70-2012 | AS TM F 1671 | 1 | GESTER | GT-RC01 |
Model | GT-RA14 |
---|---|
Mode of vibration | Pneumatic ball vibrator |
Vibration frequency | 20800 time/minute |
Vibration force | 650N |
Work table size | 40cmx40cm010 |
Work media | Marbel slab |
Experimental container | Stainless strrl expermental container |
Working positions | 6 |
Power Supply | 1Φ AC 220V 50Hz |
Model | GT-C26A |
---|---|
Testing range | 50pa-200kpa |
Water pessure increase rate | 1kpa-30kpa |
Accuracy | 0.2%F,S |
Clamping method | Pneumatic clamping |
Specimen test area | 100cm²,or7.8cm² (Option) |
Testing mode | 1) P.Rise 2) Const P&Timing 3) Const P&Time 4) Water Penetration 5) Fatigue |
Testing unit | pa,mmHg,cmH2O |
Power Supply | AC200V 50H/65Hz |
Dimensions | 600x450x640mm(LxWxH) |
Weight | 60kg |